ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

Product Details:

Place of Origin: China
Brand Name: KingPo
Certification: Calibration certificate
Model Number: KP-1023

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: To be Quoted
Delivery Time: 35
Payment Terms: T/T
Supply Ability: 25 per month

Description

Detail Information

Standard: ISO16750-4 Clause 4.2 Cycles: 100 The Holding Time Of The Specified Temperature Tmax Th: 1h Or Until The DUT Temperature Is Stable Conversion Duration: <20s (manual Conversion Between DUT Storage Temperature And Splash Temperature) Test Liquid: Deionized Water + 3% Pure Arizona Dust Or 5% Sodium Water Temperature: 0~+4°C High Light:

ozone test chamber

,

temperature and humidity chamber

,

ISO16750-4 Clause 4.2 Chamber

Product Description

 

ISO16750-4 Clause 4.2 Water Splash Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

 

Purpose 

The product used in the shallow water area of the vehicle simulates thermal shock testing caused by ice water. The purpose is to simulate the splashing of ice water into a heating system or component while driving on a wet road in winter. A failure mode is a temperature expansion coefficient that causes mechanical cracking or seal failure. Another additional failure mode, not covered in 5.3.3, is the reduction in tightness and water intrusion into systems or components.

There are two ways to perform the test (see sections 4.2 and 4.3)

 

Test

Heat the DUT (device under test) to a certain temperature max) and the specified time (hours) in an oven. Spray the ice water to the DUT for 3 seconds.

 

               

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the DUT is only splashed in one direction on the vehicle, it will only spray in the direction of the installation position. If the equipment is splashed in multiple directions on the vehicle, these directions should be stated, and each direction is tested with a new DUT. The width of the splash is always greater than the width of the DUT. If the size of the DUT that accepts splashing water is much larger than the single sprinkler head, multiple nozzles should be arranged to splash water into the DUT in rows.

 

 

Cycles 100
The holding time of the specified temperature Tmax th 1h or until the DUT temperature is stable
Conversion duration <20s (manual conversion between DUT storage temperature and splash temperature)
Test liquid Deionized water + 3% pure Arizona dust or 5% sodium
Water temperature 0~+4°C
Water flow 3L-4L/3s (jetting process)
Spout to DUT distance 325 ± 25mm (provided water should exceed the width of the DUT)
Working mode (ISO16750-1) See Figure 5
Direction of the DUT Same as loading direction