CEE7 Plug Socket Tester Plug And Socket Gauge Calibration Certificate
Product Details:
Place of Origin: | China |
Brand Name: | Kingpo |
Certification: | Calibration Certificate (ISO17025) |
Model Number: | VDE0620-1 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be quoted |
Packaging Details: | safety carton pack or plywood box |
Delivery Time: | 15 work days |
Payment Terms: | T/T |
Supply Ability: | 1000 Pieces/month |
- Description
- Reviews (0)
Description
Detail Information
CEE7 Plug Socket Tester
,
Plug And Socket Gauge
,
Calibration Certificate CEE7 Gauges
Product Description
CEE7 Plug Socket Tester , Plug And Socket Gauge Calibration Certificate
NO | Figure No. | Description |
1 | CEE7/C1 |
10/16A 250V two-pole socket-outlets Gauges c1 for size of entry holes for plug pins |
2 | CEE7/C2A.B |
10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact Gauges c2 for minimum opening of contact tubes |
3 | CEE7/C3 |
10/16A 250V two-pole socket-outlets Gauge c3 for acceptance of two-pole plugs |
4 | CEE7/C4 |
10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge c4 for acceptance of two-pole plugs with siade earthing contacts |
5 | CEE7/C6A.B |
10/16A 250V two-pole fixed socket-outlets Gauges c6 for fixing holes or slots |
6 | CEE7/C7A.B.C.D |
10/16A 250V two-pole socket-outlets Gauges c7 for distance to point of first contact |
7 | CEE7/C8 |
10/16A 250V two-pole socket-outlets Gauge c8 for wiring channel |
8 | CEE7/C9A.B |
2.5A 250V and 10/16A250V two-pole piugs and 10/16A 250V two-pole socket-outlets with pin-type earthing-contact Gauges c9 for pin diameter |
9 | CEE7/C10A.B |
10/16A 250Vtwo-pole plugs Gauges c10 for pin spacing |
10 | CEE7/C11 |
10/16A 250V two-pole socket-outlets and two-pole piugs with pin-type earthing-contact Gauge c11 for maximum opening of contact tubes |
11 | CEE7/C12 |
10/16A 250V two-pole plugs with side earthing-contacts Gauge c12 for interchangeability |
12 | CEE7/C13 |
2.5A 250V two-pole plugs for class ii appliances Gauge for interchangeability |
13 | CEE7/C14 |
10/16A 250V two-pole flush-type socket-outlets for screw fixing Gauge for dimensions of mounting boxes |
14 | CEE7/C15 |
10/16A 250V two-pole plugs without earthing contact Gauge for non-interchangeability with two-pole plugs with earthing contact |
15 | CEE7/C16 |
10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge for non-acceptance of two-pole plugs wihout earthing contact |
16 | CEE7/C18 |
10/16A 250V two-pole socket-outlets without earthing contact Gauge for checking impossibility of single-pole insertion of plugs |
17 | CEE7/C19A.B.C |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
18 | CEE7/C19a |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
19 | CEE7/C20 | Device for testing non-solid pins |
20 | CEE7/C21 | Device for checking the resistance to lateral strain of 10/16A 250V two-pole fixed socket-outlets |
21 | CEE7/C22 | Splash apparatus |
22 | CEE7/C23 | Device for measuring the contact pressure of earthing contacts of 10/16A 250V two-pole socket-outlets with side earthing-contacts |
23 | CEE7/C24 | Apparatus for breaking capacity and normal operation tests |
24 | CEE7/C25 | Circuit diagrams for bresaking capacity and normal operation tests |
25 | CEE7/C26 | Apparatus for chesking the withdrawal force |
26 | CEE7/C27 | Apparatus for testing the cord anchorage |
27 | CEE7/C28 | Apparatus for flexing test |
28 | CEE7/C29 | Impact-test apparatus |
29 | CEE7/C30 | Tumbling barrel |
30 | CEE7/C31 | Apparatus for impact test at low temperature |
31 | CEE7/C32 | Arrangement for compression test |
32 | CEE7/C33 | Apparatus for abrasion test on insulating collars of plug pins |
33 | CEE7/C34 | Ball-pressure apparatus |
34 | CEE7/C35 | Apparatus for pressure test on plugs and portable socket-outlets |
35 | CEE7/C36 | Hot mandrel apparatus |
36 | CEE7/C37 | Arrangement and dimensions of the electrodes for the tracking test |
NO | Figure No. | Description |
1 | CEE7/C1 |
10/16A 250V two-pole socket-outlets Gauges c1 for size of entry holes for plug pins |
2 | CEE7/C2A.B |
10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact Gauges c2 for minimum opening of contact tubes |
3 | CEE7/C3 |
10/16A 250V two-pole socket-outlets Gauge c3 for acceptance of two-pole plugs |
4 | CEE7/C4 |
10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge c4 for acceptance of two-pole plugs with siade earthing contacts |
5 | CEE7/C6A.B |
10/16A 250V two-pole fixed socket-outlets Gauges c6 for fixing holes or slots |
6 | CEE7/C7A.B.C.D |
10/16A 250V two-pole socket-outlets Gauges c7 for distance to point of first contact |
7 | CEE7/C8 |
10/16A 250V two-pole socket-outlets Gauge c8 for wiring channel |
8 | CEE7/C9A.B |
2.5A 250V and 10/16A250V two-pole piugs and 10/16A 250V two-pole socket-outlets with pin-type earthing-contact Gauges c9 for pin diameter |
9 | CEE7/C10A.B |
10/16A 250Vtwo-pole plugs Gauges c10 for pin spacing |
10 | CEE7/C11 |
10/16A 250V two-pole socket-outlets and two-pole piugs with pin-type earthing-contact Gauge c11 for maximum opening of contact tubes |
11 | CEE7/C12 |
10/16A 250V two-pole plugs with side earthing-contacts Gauge c12 for interchangeability |
12 | CEE7/C13 |
2.5A 250V two-pole plugs for class ii appliances Gauge for interchangeability |
13 | CEE7/C14 |
10/16A 250V two-pole flush-type socket-outlets for screw fixing Gauge for dimensions of mounting boxes |
14 | CEE7/C15 |
10/16A 250V two-pole plugs without earthing contact Gauge for non-interchangeability with two-pole plugs with earthing contact |
15 | CEE7/C16 |
10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge for non-acceptance of two-pole plugs wihout earthing contact |
16 | CEE7/C18 |
10/16A 250V two-pole socket-outlets without earthing contact Gauge for checking impossibility of single-pole insertion of plugs |
17 | CEE7/C19A.B.C |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
18 | CEE7/C19a |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
19 | CEE7/C20 | Device for testing non-solid pins |
20 | CEE7/C21 | Device for checking the resistance to lateral strain of 10/16A 250V two-pole fixed socket-outlets |
21 | CEE7/C22 | Splash apparatus |
22 | CEE7/C23 | Device for measuring the contact pressure of earthing contacts of 10/16A 250V two-pole socket-outlets with side earthing-contacts |
23 | CEE7/C24 | Apparatus for breaking capacity and normal operation tests |
24 | CEE7/C25 | Circuit diagrams for bresaking capacity and normal operation tests |
25 | CEE7/C26 | Apparatus for chesking the withdrawal force |
26 | CEE7/C27 | Apparatus for testing the cord anchorage |
27 | CEE7/C28 | Apparatus for flexing test |
28 | CEE7/C29 | Impact-test apparatus |
29 | CEE7/C30 | Tumbling barrel |
30 | CEE7/C31 | Apparatus for impact test at low temperature |
31 | CEE7/C32 | Arrangement for compression test |
32 | CEE7/C33 | Apparatus for abrasion test on insulating collars of plug pins |
33 | CEE7/C34 | Ball-pressure apparatus |
34 | CEE7/C35 | Apparatus for pressure test on plugs and portable socket-outlets |
35 | CEE7/C36 | Hot mandrel apparatus |
36 | CEE7/C37 | Arrangement and dimensions of the electrodes for the tracking test |
Reviews
There are no reviews yet.