AVR APA6000 series
Product parameter
• Input voltage range:1Ø2W+G 110V/220V±10% 3Ø4W+G 220V/380V±10%
• Load Regulation≤1% Waveform Distortion≤3%
• The unbalanced three-phase load ≤30%, the unbalanced output voltage ≤ 3%.
• Full load can be used for a long time, and the voltage can be regulated continuously for a short time within 30% of overload.
Product details
High Performance
• High voltage stabilization rate, low harmonic distortion, suitable for the use of voltage stabilization of terminal equipment
• Purification ability, protection equipment use in complex power grid environment
• Slow start characteristic to prevent sudden wave damage of inductive load
• No active elements, simple operation, maintenance-free, with RC circuit, can eliminate IMPULSE and add shock absorber, prevent PULSE interference.
• Pointer voltmeter, ammeter, accurate and intuitive
• The operation mode is humanized, does not touch the strong electric part, and the panel button directly controls the power on and off. It is simple and safe.
• No noise source, quiet and comfortable environment
• Divided into Type A(100/110V 60Hz), Type B(200/220v 50Hz), Type C(100/200V 110/220V 50Hz)
Suitable place
Computer Center, Industrial Equipment,Medical Equipment, Transaction Equipment, Household Appliances Auto-plug-in Programming Machine, Automatic Testing Equipment, Laboratory, Inspection Unit, Communication Equipment,SMT equipment, OA equipment, CNC equipment, production line requirements equipment, etc.
APA6000 Single phase series
Model | 6005 | 6010 | 6015 | 6020 | 6030 | 6050 | |
---|---|---|---|---|---|---|---|
Capacity | 5KVA | 10KVA | 15KVA | 20KVA | 30KVA | 50KVA | |
Input | Voltage | Type A 110V Type B 220V Type C 110V 220V | |||||
Frequency | 50/60Hz ±3Hz | ||||||
Range | 15%/+10%~-20% | ||||||
Output | Voltage | Type A 100V 110V 120V Type B 200V 220V 240V Type C 100V/200V 110V/220V(Isolation) | |||||
Regulation | ≦1% | ||||||
Distortion | ≦3% | ||||||
Power factor | 0.8~1 | ||||||
Response time | 0≦0.5 circle reaction~Voltage stabilization in 5 circle≦80ms | ||||||
Efficiency | 90%~95% | ||||||
Protection | Short circuit and overload protection | ||||||
Working environment | ambient temperature 0~40°C relative humidity10~90% |
APA6000S Three phase series
Model | 6015S | 6020S | 6030S | 6045S | 6060S | 6075S | |
---|---|---|---|---|---|---|---|
Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | |
Input | Voltage | Type B 3Ø3W+G 220V/380V Type C 3Ø4W+G 110V/190V 120/208V 220V/380V | |||||
Frequency | 50/60Hz ±3Hz | ||||||
Range | 15%/+10%~-20% | ||||||
Output | Voltage | Type B 200V 220V 240V Type C 110V/190V 120/208V 220V/380V(Isolation) | |||||
Regulation | ≦1% | ||||||
Distortion | ≦3% | ||||||
Power factor | 0.8~1 | ||||||
Response time | 0≦0.5 circle reaction~Voltage stabilization in 5 circle≦80ms | ||||||
Efficiency | 90%~95% | ||||||
Protection | Short circuit and overload protection | ||||||
Working environment | ambient temperature 0~40°C relative humidity10~90% |
Customized Services
To fulfill the diversified needs for clients, we gain experience of research and achieve flexible production.
Standard Mastery
Extensive experiences of customized business and understanding of each standard.
Thorough Services
Serving with a grateful, professional and honorable attitude, we established our own independent service branch to provide you with long-term value adding services.
Experienced R&D Team
Extensive experiences of Research and Development for mechanics, electronics, optics, thermology, IT technology and customer services.
Overall Matching
Solutions provider for laboratories based on standards or functions required.
Company Profile
KINGPO company extensive research and development experiences regarding safety performance testing, electromechanical properties testing, fireproof and flame retardant performance testing, waterproof performance testing and life testing for the household electrical appliances, electronic and electrical products, electrical accessories, building components and materials, wire and cable, IT computer and communications, children's toys and textiles, power simulate load and capacitor and so on.
Also manufacture the testing equipment for all kind of products, sampling laboratory and line automatic detecting system.
With the nationally recognized testing instrumentation production license. More than 1000 kinds of products.
packaging & shipping
Packaging: Wooden Box
Shipping: ocean
Port: Shenzhen port or Customer's required
Payment & Delivery
Payment method: T/T, money Gram, Paypal, Western Union
Payment currency: USD, HKD, CNY
Delivery: 10-40 days received the deposit.
FAQ
Why choose us?
Customized Services
To fulfill the diversified needs for clients, we gain experience of research and achieve flexible production.
Standard Mastery
Extensive experiences of customized business and understanding of each standard.
Thorough Services
Serving with a grateful, professional and honorable attitude, we established our own independent service branch to provide you with long-term value adding services.
Experienced R&D Team
Extensive experiences of Research and Development for mechanics, electronics, optics, thermology, IT technology and customer services.
Overall Matching
Solutions provider for laboratories based on standards or functions required.
KingPo testing equipment(DONGGUAN) Co., Ltd is engages and specialized in testing equipment with good quality and pretty competitive prices for more than 20 years, belonging to the high-tech enterprises. We always pursue the perfection with you.
What kind of your corporation?
We're the China testing machine manufacturer and trader.
What's your delivery time?
Normally, it is 10-40 days according to the unload port.
Contacts
KingPo testing equipment(DONGGUAN) Co., Ltd Tel: +86-769-81627526 Fax: +86-769-89032367 Email: info@kingpo.hk Add: No. 9 University Road, Songshan Lake, Dongguan City 523770, China |
TAG: iec tester, laboratory test equipment,iec testing equipment
Product details
High Performance
• Optional dual output, suitable for multi-load applications
• Quick stop output with emergency stop button
• With EF signal interlocking function
APA5000(AC)Single phase series
Model | 5000 | 5001 | 5002 | 5003 | 5005 | 5015 | 5020 | 5030 |
---|---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 15KVA | 20KVA | 30KVA |
Input Power | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz±3Hz | ||||||||
Output Frequency | Vertical/trailer type 300~ 500Hz 400Hz (Special frequencies are customized) | |||||||
Output Voltage | 115V/220V±10%(Special Voltage Accepts Customization) Resolving power 0.1V accuracy 0.5%F.S.+4counts |
|||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 126/63 | 168/84 | 250/125 |
Resolving power0.01A(500VA,1KVA) 0.1A(1KVA以上) accuracy 0.2%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | ≤1.5% (Resistive load) |
||||||
Waveform Distortion | ≤2%(Resistive load) | ≤3% (Resistive load) |
||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Input and output are equipped with no fuse switch, overload, over-current, temperature, short circuit, over-voltage/under-voltage protection and alarm | |||||||
Overload capacity | 120%(1H)150%(1M)200%(15S)Other specifications are optional (According to 25% work cycle Duty Cycle Test results) |
|||||||
Weight(kg) | 20 | 25 | 30 | 35 | 45 | 190 | 240 | 3500 |
W*H*D(mm) | 425*89*480 | 430*200*500 | 430*580*700 | 600*1260*700 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |
APA5000S(AC)Three phase series
Model | 5015S | 5020S | 5030S | 5045S | 5060S | 5075S | 5100S | 5120S |
---|---|---|---|---|---|---|---|---|
Output Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input Power | 3Ø4W+G 220V/380V±15% | |||||||
50/60Hz±3Hz | ||||||||
Output Frequency | 400Hz(Trailer type)/300~ 500Hz (Vertical type)Resolving power 0.01Hz accuracy±0.02%F.S. | |||||||
Output Voltage | 115/200V±15V Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Resolving power 0.1A accuracy 0.5%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | |||||||
Waveform Distortion | ≤2% (Resistive load) | |||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Over-voltage/under-voltage phase-gap protection and alarm with overload, over-current and over-temperature short circuit |
|||||||
Overload capacity | 125%(600S)150%(30S)200%(10S)Other specifications are optional | |||||||
(kg)Weight | 210 | 230 | 270 | 360 | 450 | 540 | 600 | 800 |
(mm)W*H*D | 510*780*710 | 600*1260*700 | 750*1500*850 | 900*1780*950 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |