15mm Length IEC 60601-1- Test Pin for Medical Equipment Testing
Product Details:
Place of Origin: | China |
Brand Name: | KingPo |
Certification: | Calibration Certificate |
Model Number: | KP-TP61B |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be quoted |
Packaging Details: | safety carton pack or plywood box |
Delivery Time: | 7 working days |
Payment Terms: | T/T |
Supply Ability: | 50 pcs per month |
- Description
- Reviews (0)
Description
Detail Information
3/4mm test pin
,
14mm test pin
,
IEC 60601-1 Test Pin
Product Description
IEC 60601-1-Test Pin
According to IEC 60601-1-figure 8
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60601-1:2005 + Am.1:2012
Medical electrical equipment – Part 1: General requirements for basic safety and essential performance
Clause | Measurement/testing | Testing / measuring equipment / material needed | Subcontracting |
4.11 | Power input |
Suitable devices for the voltage, current/power and frequency Supply: 1 phase and 3 phase variacs
|
R |
5.3 | Ambient temperature, humidity, atmospheric pressure |
Suitable devices for recording ambient temperature, humidity, atmospheric pressure
|
R |
5.7 | Humidity preconditioning treatment |
Environmental conditions: Climate chamber controlling temperature and humidity
|
R |
5.9.2 | Accessible parts |
Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7)
|
R |
7.1.2 | Legibility of markings |
Illuminance meter
|
R |
7.1.3 | Durability of markings |
Distilled water, ethanol (96% pure), isopropyl alcohol , timer / stop watch
|
R |
8.4.2 | Accessible parts including applied parts |
Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N)
|
R |
8.4.3, 8.4.4 |
Limitations voltage and energy | Suitable oscilloscope recorder /set-up & RCL meter | R |
8.5.5.1 | Defibrillation protection |
5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope
|
S |
8.5.5.2 | Energy reduction test |
The test circuit according to Figure 11, oscilloscope, oscilloscope leads
|
S |
8.6.4 | Impedance and current-carrying capability |
Current source (25 A minimum, 50 or 60 Hz, 6 V maximum)
|
R |
8.7 | Leakage currents and patient auxiliary currents |
Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20)
|
R |
8.8.3 | Dielectric strength |
High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch / timer
|
R |
8.8.4.1 a) | Ball pressure test |
Test equipment according to IEC 60695-10-2
|
R |
8.8.4.2 | Resistance to environmental stress |
Apparatus for ageing rubber in oxygen
|
S |
8.9 | Creepage distances and air clearances |
Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6)
|
R |
8.9.1.7 | Material groups classification |
Test equipment according to IEC 60112
|
S |
8.9.3.4 | Thermal cycling |
Heating cabinet
|
R |
8.11.3.5 | Cord anchorage |
Force gauge (at least 100 N), torque gauge (at least 0.35 Nm)
|
R |
8.11.3.6 | Cord guards |
Weights, angle gauge, radius gauge
|
R |
9.4 | Instability hazards |
5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch / timer
|
R |
9.5.2 | Cathode ray tubes |
The relevant tests of IEC 60065, Clause 18.
|
S |
9.6.2.1 | Audible acoustic energy |
A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1
|
S |
9.6.3 | Hand-transmitted vibration |
Measurements are made in accordance with ISO 5349-1.
|
S |
9.7.5 | Pressure vessels |
Hydraulic pressure test apparatus
|
S |
9.8 | Hazards associated with support systems |
Weights or load cell, 0.1 m2 test surface, stop watch / timer, human body test mass (Figure 33)
|
R |
10.1 | X-radiation |
Radiation meter
|
S |
10.3 | Microwave radiation |
Radiation meter
|
S |
10.4 | Lasers | Test equipment according to IEC 60825-1 | S |
11.1 | Excessive temperatures |
Temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, test corner, variac
|
R |
11.2 | Fire prevention |
Spark ignition test apparatus (Figure 34), oxygen gas analyzer
|
S |
11.3 | Constructional requirements for fire enclosures | FV tests specified in IEC 60695-11-10 | S |
11.6.2 | Overflow |
15° inclined plane or inclinometer or trigonometric calculation, stop watch / timer, high voltage tester
|
R |
11.6.3 | Spillage |
Flask or graduated cylinder, stop watch / timer
|
R |
11.6.5 | Ingress of water or particulate matter |
Classification tests of IEC 60529
|
W |
11.6.6 | Cleaning and disinfection |
Dielectric strength and leakage current tests as appropriate
|
R |
11.6.7 | Sterilization |
Sterilisation to client specification
|
S |
13 | Hazardous situations and fault conditions |
stop watch / timer, voltmeter, ammeter, temperature indicator / recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth
|
R |
15.3 | Mechanical strength |
Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven
|
R |
15.4.2 | Temperature and overload control devices |
Positive temperature coefficient devices (PTC’s) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17
|
S |
15.4.3.4 | Primary Lithium batteries |
Performance of the tests identified in IEC 60086-4
|
S |
15.4.3.4 | Secondary Lithium batteries | Performance of the tests identified in IEC 62133 | S |
15.4.6 | Actuating parts of controls |
Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch / timer
|
R |
15.4.7 | Cord-connected hand-held and foot-operated control devices |
Force gauge (minimum1 350 N), 30 mm diameter test tool, stop watch / timer
|
R |
15.4.7.3 | Entry of liquids |
Classification tests of IEC 60529
|
W |
15.5.1.1 | Transformers |
Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads
|
R |
15.5.2 | Dielectric strength |
5x voltage / 5x frequency dielectric strength test fixture, stop watch / timer
|
R |
16.6 | Leakage currents |
As in sub-clause 8.7
|
R |
A 10.4 | Light emitting diodes (LEDs) |
As specified in IEC 62471
|
S |
G | Protection against hazards of ignition of flammable anaesthetic mixtures |
4 mm & 12 mm diameter test rods, timer / stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, oxygen mixture ( volume percentage 12,2 % ± 0,4 %),test apparatus for flammable mixtures (Figure G.7),
|
S |
G.4.3 | Prevention of electrostatic charges |
antistatic material testing according to ISO 2882
|
S |
L | Insulated winding wires for use without interleaved insulation | Sample is preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron. | S |