Accurate Control Odor Testing Equipment , Odour Measurement Equipment
Product Details:
Place of Origin: | China |
Brand Name: | KingPo |
Certification: | Calibration Certificate |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be quoted |
Packaging Details: | safety carton pack or plywood box |
Delivery Time: | 35 working days |
Payment Terms: | T/T |
Supply Ability: | 3 sets per month |
- Description
- Reviews (0)
Description
Detail Information
temperature and humidity chamber
,
climatic test chamber
Product Description
Odor Test Chamber
Product purpose
High temperature test chamber can be used to test and confirm the odor detection and testing with small sampling bag method of storage and usage of such products as Electrician,electronics,automotive electrical materials,agricultural products and leather under high temp.
Feature
Accurate control of temp. and wind speed is achieved through advanced controller,among which air circulation system within the chamber controls the direction and flow rate of air flow in the chamber ,while program settings of the control system reaches the function of temp. change and provides the environmental conditions required for odor test automatically.High temp. chamber is sealed with low odor volatile materials of full welded,and its air should be exchanged with clean air outside.
Reference Standards
• GB/T 2423.2-2001 Test B:high temeprature test method
• GJB 150.3-1986 high temperature test
• IEC68-2-2 Test B:dry heat
• GB11158 Techinical conditions of high temperature test chamber
• GB/T2423.2 Basic Environment of Electric and Electronic Products Test
• QJQ 11052-2010 Odor test method for interiors of vehicles
• MS 300-34 Odor test method for interior of vehicles
• GB/T18885-2009 Ecological textile
• QB/T2725-2005 Determination of Leather Odor
• GB18401-2003 Specifications for Basie Safety Technology of National Textile
Technical Parameters:
Model | V-0V-216 | V-0V-768 | V-0V-1000 | V-0V-4000 | V-0V-8000 | |
Volume | 216 | 768 | 1000 | 4000 | 8000 | |
Performance | temp. range | Environmental temp ±20℃~+200℃ | ||||
temp. fluctuation | If ≤100℃,0.4℃;≤200℃,0.,8℃ | |||||
temp. deviation | If ≤100℃,±1.5℃;≤200℃,±2℃ | |||||
heating-up time | Environmental temp ±20℃~+200℃ | |||||
≤60min | ||||||
Internal dimension | 600*600*600 | 830*1200*800 | 1000*1000*1000 | 2000*1000*2000 | 2000*2000*2000 | |
External dimension | 800*1200*1295 | 1030*1800*1495 | 1730*1480*1275 | 2700*1800*2750 | 2700*2400*3200 | |
Temperature and humidity regulating method | Forced hot wind circulation ventilation mode | |||||
working environment temp. | 0~+40℃ | |||||
Material | Shell | Double galvanized plates,surface spray treatment | ||||
Inner tanks | stainless steel SUS201/8K,mirror plate | |||||
Heat preservation | glass fibre | |||||
Heater | Ni Cr alloy fin type electric heater | |||||
draught fan | Axial flow fan | |||||
ventilation door | Manual switching(opening degree is adjustable) | |||||
Controller | Operation mode | Program operation controller | ||||
setting range | 0~+120℃ | |||||
setting accuracy | Temp:1℃, time : 1min | |||||
Display resolution | Temp : 0.1℃, time : 1min | |||||
Operating interface | according to the setting mode | |||||
control method | PID+SSR | |||||
Input | K type thermocouple | |||||
Auxillary function | Input disconnection,detection function,uooer limit temperature alarm function,buzzer alarm function,automatic temperature overhet prevention function,abnormal indication,alarm number display.self-diagnosis function and temp. and time keeping function. | |||||
Installed capacity(Kw) | 6 | 8 | 9 | 15 | 20 | |
Standard configuration | 2 sets of sample holders,1 piece of power line(6 meters long) and 1 set of rubber plug and cap of pin hole | |||||
Power | AC380V 3 phases 4 lines + protective earth wire | |||||
Mounting device | leakage circuit breaker for the power,overheat protector(upper limit temperature alarm function,fan motor overheat protection switch,control circuit short circuit protection fuse and over temp. protector | |||||
Optional | Pin hole(Ω50mm Ω100mm); Rubber plug of pin hold(Ω50mm Ω100mm,cooperative use with pin hole); Sample holder,reinforced inner box and chassis,timer meter and temp. grapher; Emergency stop switch,remote monitoring operation,external alarm output terminal, exhaust flange and stainless steel exhaust elbow | |||||
Additional products for optional choice smell box(patented product) | standard odor smell chamber can be provided,uniform smell test can be realized,and accurate control of temperature,relative humidity,wind speed and indoor air cleanliness can be provided.External standard gases can be controlled with micro elements such as solenoid valve(handle valve) and flowmeter,so that the result of smell test can be more stable,accurate,scientific and standardized. |
Note:
※ When indoor temperature is ±25℃,it will be under circulating operation without test sample conditions or data measured when exchanging air.
※ Fluctuation is indicated according to the rules of GB/T5170.2-1996,it shows ±0.2℃,±0.4℃ or ±0.6℃
※ Excluding the part with convex shape
※ Optional air inlet purifying device,whose height is incresed by 350mm
※ 4 standard configurations of sampling port,with 12 sampling ports optional.
※ can be used for smell test,ordinary high temp. Chamber test and small sampling bag method test.