High Efficient Formaldehyde Testing Equipment With Calibration Certificate
Product Details:
Place of Origin: | China |
Brand Name: | KingPo |
Certification: | Calibration Certificate |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be quoted |
Packaging Details: | safety carton pack or plywood box |
Delivery Time: | 35 working days |
Payment Terms: | T/T |
Supply Ability: | 3 sets per month |
- Description
- Reviews (0)
Description
Detail Information
ozone test chamber
,
temperature and humidity chamber
Product Description
Formaldehyde Release Capsule
Usage:
* confirm the influence of environment variables on the release rate and release properties of materials and products;
* Grade materials and products according to their release properties;
* Develop and validate the proposed model of indoor air pollutions;
* Evaluate indoor air quality(IAQ) according to the data and proposed model of indoor pollutants;
Reference Standards:
* GB 18580 ''Indoor Decorating and Renovating Materials Limit of Formaldehyde Emission of Manmade Board and its Products''
* GB 18587 ''Indoor Decorating and Renovating Materials Releasing Limitation of Harmful Substances from Carpet,Carpet Pad and Carpet Adhesive''
* GB 18584 ''Indoor Decorating and Renovating Materials Limits of Harmful Substances from Wooden Furniture(Exposure draft)
* Upholstered Furniture Limits of Harmful Substances from Sofa(Exposure draft) and Climate Chamber for Detection of Volatile Organic Compounds in Furniture(Exposure draft)
* LY/T1980-2011 "Detection Box for Release Quantity of Volatile Organic Compounds(VOC) and Formaldehyde LY/T 1981-2011 Detection Box for Release Quantity of Formaldehyde with Gas Analysis Method"
* LY/T1982-2011 "Large Climate Chamber for Detection of Release Quantity of Formaldehyde of Manmade Board and its Products"
Technical Parameters:
Product Model |
C-50 |
C-100 |
C-250 |
C-500 |
C-1000 |
|||
Volume of chamber(WxDxH) |
56*30*30 |
63*40*40 |
70*60*60 |
102*70*70 |
158*80*80 |
|||
Environmental temperature |
5~35℃ |
|||||||
Environmental humidity |
≤90%R.H |
|||||||
Requirements for Environmental |
Cleanliness No pollutant source in the surrounding environment TVOC 500μg/m³ |
|||||||
Adjustable range of temperature |
10~40℃ high temperature cleaning 250℃ |
|||||||
Adjustable range of humidity |
40~70%R.H(20℃~30℃) |
|||||||
Pressure |
10±5pa |
|||||||
Temperature fluctuation |
±0.3℃(fluctuation) |
|||||||
Temperature deviation |
±0.5℃(deviation) |
|||||||
Humidity fluctuation |
±2.5%R.H |
|||||||
Humidity deviation |
±3% |
|||||||
Air exchange rate |
0.2~5/h±5%(optional 0.2~3/h±5%) |
|||||||
Air velocity |
0.1m/s 0.3m/s(Range) |
|||||||
Power |
Alternating current 380V/50Hz three-phase power supply 4/5 wiring system |
|||||||
Starting power |
11kw |
18kw |
30kw |
35kw |
||||
Operating power |
5kw |
8kw |
14kw |
16kw |
||||
Rate of recovery |
Formaldehyde have a recovery rate larger than 90% |
|||||||
Clean air system |
Standard configuration |
|||||||
Background concentration for formaldehyde |
smaller than 15μg/m³,the lowest 6μg/m³
|
Reviews
There are no reviews yet.