IEC 60598-1-Clause 4.12.5 Glands Testing , Test Rods , Screws And Connections And Glands Testing

Product Details:

Place of Origin: China
Brand Name: KingPo
Certification: Calibration Certificate
Model Number: IEC 60598-1-clause 4.12.5

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: To be quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: 100 sets per month
Payment Terms: T/T

Description

Detail Information

Standard: IEC 60598-1 Clause 4.12.5 Diameter Of The Disc: 500mm Cylindrical Metal Rod: 14pcs In Total Weights: 15N,20N,25N,30N ,40N High Light:

IEC 60598-1-Clause 4.12.5

,

IEC 60884-1 2013 clause 24.6

,

glands testing Equipment

Product Description

IEC 60598-1-clause 4.12.5 glands testing , Test rods , Screws and connections and glands testing

 

Standard: IEC 60884-1 2013 clause 24.6, IEC 60598-1 clause 4.12.5

 

Application: This device is use for test the torque resistance strength of screwed gland of lamps and similar appliances.

 

Test sample: Screwed gland of lamps and similar appliances.

 

Feature: Floor type support, lifting weights mechanism drive turntable to achieve torque test.

 

Parameters:

  1. Cylindrical metal rod: Ф5, Ф7, Ф9, Ф10, Ф12, Ф14, Ф16, Ф18, Ф20, Ф22, Ф25, Ф30, Ф32, Ф40mm, one each, 14 pc in all
  2. Weights: 20N, 40N, 50N, 60N weight with hook, one each; 10N, 20N weight with hole, one each. Can meet the test requirements to most screwed glands.
  3. Diameter of the disc: 250mm(500mm disc for option, with less weights)
Diameter of test rod(mm) Metal glands(N.m) Glands of moulded material(N.m)
<7 6.25 2.5
7~14 6.25 3.75
14~20 7.5 5
>20 10 7.5
 

 

 

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC 60598-1:2014, A1:2017 Edition 8.1
Luminaires – Part 1: General requirements and tests

Clause Measurement/testing Testing / measuring equipment / material needed Equipment Classification
3.4 Test of marking Piece of cloth / Water / Petroleum spirit R
4.4.4 Lampholder pressure test Test caps / Pressure device / Torque driver R
4.4.5 Voltage across lampholders High voltage probe / Oscilloscope R
4.11.6 Electro-mechanical contact system Low voltage variable current power supply, voltmeter, high voltage transformer R
4.12.1 / 4.12.5 Screws and connections (mechanical) and glands testing Test screwdriver or spanner / Test rods R
4.13.1/4.13.4 4.13.6/4.21.4

 

Mechanical strength tests

Spring-operated impact test apparatus / Apparatus for ball impact tests Conditioning cabinet (e.g. freezer) / Angle measuring device / Weighting device / Tumbling barrel test equipment

 

R

4.14.1/4.14.2

4.14.3

Adjusting devices testing Glass test shelves / Weighting device / Test apparatus for adjustable devices R
4.9.2/4.18.1 Insulating linings and sleeves tests / Resistance to corrosion Heating cabinet, humidity cabinet, megaohmeter, high voltage transformer R

 

 

4.18.2/Annex F Stress corrosion Closeable glass vessel / test solution / Heating cabinet / Facilities to wash samples after test R
4.20 Rough service luminaires Vibration test equipment S
4.22 Attachment to lamps Weighing device R

 

4.24/Annex P

 

Photobiological hazard: UV radiation, retinal blue light hazard

  • UV radiation test instruments / retinal blue light hazard test instruments (Equipment List of IEC/TR 62778
  • Goniophotometric measurement system

S

 

S

4.26 Short circuit protection test Test chain / Weighting device R
4.28 Fixing of thermal sensing controls Temperature change test instruments in accordance to IEC 60068-2-14, test Na S
5.2.10.1 Pull and torque tests on cord anchorage Cord anchorage tests apparatus (pull and torque) R
5.3 Internal wiring dimensions Micrometer / Equipment for insulation thickness R
5.4 Test of conductors having a reduced cross-sectional area Thermometer / Thermocouples / Ammeter / Adjustable resistive load R
7.2.3 Earth continuity test Earthing test equipment R

8.2.5

8.2.7

Protection against electric shock tests / Capacitor discharge

Standard test finger (IEC 60529) / Unjointed test finger

Voltmeter / oscilloscope

R

 

9.2.0 Solid object proof luminaire testing IP 3X (2,5 mm) / IP 4X (1 mm) probes R
9.2.1 / 9.2.2 Dust proof luminaire tests Apparatus for proving protection against dust R
9.2.3,4,5,6,7, 8,9 Water proof luminaires testing Apparatus for protection against water tests R
9.3.1 Humidity tests Humidity cabinet R
10.2.1 Insulation resistance tests Megaohmmeter R
10.2.2 Electric strength tests High voltage transformer R
10.3.1 Leakage current testing Leakage current tester R

 

 

11.2.1 Creepage distances and clearances measurements Digital calliper (or equivalent) / Oscilloscope R
12.3.1 Endurance tests Thermal cabinet (35°C) / Endurance test equipment / Multimeter / Wattmeter R

 

12.4.1

 

Thermal tests

Draught-proof enclosure (25°C) or alternative chamber/room / Thermometer / Thermocouples / Voltage stabilizer / Multimeter / Wattmeter

 

R

12.5.1e)

Annex C

Fig. C3

 

Abnormal operation testing

 

Test circuit for metal halide luminaires

 

R

 

12.7.2

Test for luminaires with temperature sensing controls internal/external to the ballast or transformer Relevant equipment of clauses 15.3 and 20.6, Equipment List of IEC 61558-1:2005

 

R

13.2.1 Resistance to heat test Heating cabinet / Ball pressure test apparatus (see also CTL DSH 391 D) R
13.3.1 Resistance to flame test Needle flame test apparatus R
13.3.2 Resistance to ignition testing Glow-wire test apparatus R
13.4.1 Resistance to tracking test Proof tracking test device R
14 Screw terminals Torque drivers, test cables, pull device, micrometer, timer R
15 Screwless terminals Pull device, variable current source, voltmeter, heating cabinet, timer, test cables R

 

 

Reviews

There are no reviews yet.


Be the first to review “IEC 60598-1-Clause 4.12.5 Glands Testing , Test Rods , Screws And Connections And Glands Testing”

Related products