MS2621GNS Series Program Control Leakage Current Tester
Product Details:
Model Number: | MS2621GNS |
- Description
- Reviews (0)
Description
Detail Information
MS2621GNS Leakage Current Tester
,
1MHz Leakage Current Tester
,
99.9ua dc leakage current tester
Product Description
Welcome to use our instrument. Please check the accessories by referring to the list of attachments after the instruction after opening the instrument package. Please read this instruction carefully before use. I. OverviewThe MS2621GNS series leakage current tester is mainly used to detect leakage current of medical equipment or laboratory standard equipment. The instrument applies to the detection of the earth leakage current, housing leakage current, patient leakage current, patient leakage current (applied voltage test of signal part), patient leakage current (applied voltage test of applied part) and patient auxiliary current (DC and AC) of medical electrical equipment in various types (class I, class II, internal power supply and B type, BF type, CF type). The instrument meets the standard test requirements of Medical Electrical Equipment Part I – General Requirements for Safety (GB9706.1) and Safety Requirements For Laboratory (GB4793.1), and is the essential safety regulation test instrument for medical device manufacturers and test authorities. Main characteristics:1. It can set test items according to the category, such as automatically combining the tests in the same test item, and synchronously displaying the measured voltage value, external voltage value, normal state leakage current value, and single fault state leakage current value;2. It can complete the tests of earth leakage current, housing leakage current, patient part leakage current (applied network power voltage test of applied part), patient leakage current (DC and AC) and other items by pressing one button, and test them separately;3. It has the power supply circuit overvoltage and overcurrent protection, MD measuring device overcurrent protection, and leakage current over-limit acousto-optic alarm function. 4. It has PLC interfaces for external control; it has an RS232 interface to upload test data in real time. II. Main Technical Indicators and Parameters1. Working environment:a. Temperature :0℃ – 40℃b. Relative humidity: no more than 80%.c. There is no strong electromagnetic interference source around, no large amount of dust or corrosion gas, and the ventilation is good. 2. Power supply: AC 220V±5%; 50Hz ± 2Hz 3. Instrument power consumption: no more than 50 W. 4. Measuring device: Automatic range switching, true effective value measurement.(1) Medical GB9706.1-2007 standardsa. leakage current measurement range:I 3 – 99.9 (μA) Resolution: 0.1μAII 100.0 – 999.9 (μA) Resolution: 0.1μAIII 1000 – 9999 (μA) Resolution: 1μAb. Leakage current and auxiliary current in patient parts: DC measurement range :3 – 99.9 (μA) Resolution: 0.1μAc. Measurement accuracy: ±5%. Note: the accuracy range is more than 10μA.d. Frequency range: DC – 1MHze. Measurement impedance circuit (MD): conform to GB9706.1-2007 Figure 15 (2) Laboratory GB4793.1-2007 standardsa. Leakage current measurement range AC:I 3 – 99.9 (μA) Resolution: 0.1μAII 100.0 – 999.9 (μA) Resolution: 0.1μAIII 1000 – 9999 (μA) Resolution: 1μAb. Measurement accuracy: ±5%. Note: the accuracy range is more than 50μA.c. Measurement impedance circuit (MD): conform to GB4793.1-2007 Figure A.1 5. Output voltage:a. Measure voltage output range of power supply: 100 V – 250 V; resolution: 1 V.b. Accuracy: ±4%; add 2 words in read value.c. Capacity: MS2621GNS 300VA; MS2621GNS-IA 500VA; MS2621GNS-IB 1000VA 6. Timing device:1) Range :3 – 9999(s) resolution: 1 s2) Accuracy: ±5%
- Instructions of each part of the panel:
(1) “Power” switch: press the power switch to power on the instrument.(2) “Start” key: press the key, and the instrument starts a testing.(3) “Reset” button: press the key to stop the test; if there is an over leakage alarm, press the key to stop the alarm.(4) “SET” key: instrument setting key, press to enter parameter setting state.(5) “∨” key: press this key to reduce the value when setting parameters.(6) “∧” key: press this key to increase the value when setting parameters.(7) “ENT” key: press this key to save the set data and return to standby mode.(8) “LCD screen”: information display window.(9) Voltage regulating knob: turn this knob to adjust the output voltage, clockwise for boost, counterclockwise for reduction voltage, counterclockwise to the end at ordinary times.(10) “Test” indicator: it indicates that the leak test voltage has been output.(11) “PASS” indicator: it indicates that the tested object is qualified.(12) “NG” indicator: it indicates that the over-leakage alarm is not up to standard.
- “S1” indicator: when the instrument is testing in a single fault state of the power supply, the indicator lights on, corresponding to the “S1” switch in standard 9706.
- “S5/S9” indicator: it is the commutation indicator, corresponding to “S5/S9” switch in Standard 9706.
- “S7” indicator: this indicator indicates the “PE” port is connected, corresponding to the “S7” switch in Standard 9706.
- “S10” indicator: this indicator indicates the “FE” port is connected, corresponding to the “S10” switch in Standard 9706.
- “S12/S13” indicator: this indicator indicates that the “AP” port is connected, corresponding to the “S12” and “S13” switches in Standard 9706.
(18) “MD” jack: MD high terminal.(19) “MD” jack: MD low terminal.(20) “AP” jacks: corresponding to the S12 or S13 in 9706.1 standard.(21) Ground terminal jack: reliably grounded (this port may not be connected when the power or rear panel is reliably grounded).(22) “PE” jack: protective grounding jack(23) “FE” jack: function grounding jack.(24) “Continuous” button: it is used to switch between the “single mode test” and “multi mode continuous test”; it is “single mode test” when the button is popped up, and “multi mode continuous test” when the button is pressed down.(25) “Category select” button: press this button for class I test; pop up this button for class II and internal power test.(26) “Category select” button: press this button for class II test; pop up this button for class I and internal power test.(27) “Category select” button: press this button for internal power test; pop up this button for class I and class II test.(28) Ground jack: MD high terminal; in multi-mode combination test, it connects the “PE” terminal of the tested equipment to measure the ground leakage current.(29) “Housing” jack: MD high terminal; in multi-mode combination test, it connects the “housing” of the tested equipment to measure the leakage current of the housing.(30) “Patient” jack: MD high terminal; in multi-mode combination test, it connects the “applied part” of the tested equipment to measure the patient leakage current from the F type applied part to the ground caused by the external voltage in the single fault state.(31) Output power jack: Test voltage output terminal.(32) “Auxiliary Power”: Auxiliary voltage output.(33) “Auxiliary Power”: Auxiliary voltage output.(34) “PLC” interface: it is a standard nine-core jack.(35) “RS232” interface: it is a RS232 serial communication interface.(36) Grounding terminal: it is a housing ground terminal.(37) Power outlet: input AC220V, 50Hz power supply, with internal fuse.