UL 310 Table 3 ( Ninth Edition ) Test Tab For Safety For Electrical Quick – Connect Terminals

Product Details:

Place of Origin: China
Brand Name: Kingpo
Certification: Calibration Certificate

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: To be quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: goods in stock
Payment Terms: T/T
Supply Ability: 1000 pcs

Description

Detail Information

Standard: UL 310 Table 3(Ninth Edition) Purpose: For Safety For Electrical Quick-Connect Terminals, High Light:

articulated finger probe

,

jointed test finger

Product Description

 

UL Standard for Safety for Electrical Quick-Connect Terminals,
UL 310

Ninth Edition

5.2.2 Test tab

5.2.2.1 Test tabs for the insertion-withdrawal test described in Clause 6.4 shall be made of unplated brass, identified as CDA C26000 Alloy with a hardness of 62 ±7 on the Rockwell 30T scale.

5.2.2.2 Test tabs for the temperature and current cycling tests described in Clause 6.5 shall be made of tin-plated steel or corrosion resistant steel having a hardness of 68 ±5 on the Rockwell 30T scale.

5.2.2.3 In regard to Clause 5.2.2.2, for connectors intended exclusively for use with production tabs of copper alloy, an unplated brass test tab of C26000 Alloy with a hardness of 62 ±7 on the Rockwell 30T scale may be used.

5.3.3 Test tab

5.3.3.1 Single-ended test tabs for the insertion-withdrawal test shall have the configuration shown in Figures 2 to 4 and the dimensions specified in Tables 2 and 3. The "C" dimension tolerance shall be ±0.008 mm (0.0003 in) for brass and ±0.013 mm (0.0005 in) for steel, and raised plateaus around the detent shall be limited to a combined total of 0.03 mm (0.001 in) for both sides.

5.3.3.2 Double-ended test tabs for the temperature and current cycling tests shall be constructed in accordance with Clause 5.3.3.1 and have the configuration shown in Figure 5.

Table 3

Dimensions of metric production and test tabs in millimeters

 

(See note to Figure 5)

 

Nominal size A B(min) C D E F J M N P Q(min)
2.8 x 0.5 with dimple 0.6 7.0 0.54 2.90 1.8 1.3 12° 1.7 1.4 1.4 8.1
0.3 0.47 2.70 1.3 1.1 1.4 1.0 0.3
2.8 x 0.5 with hole 0.6 7.0 0.54 2.90 1.8 1.3 12°     1.4 8.1
0.3 0.47 2.70 1.3 1.1     0.3
2.8 x 0.8 with dimple 0.6 7.0 0.84 2.90 1.8 1.3 12° 1.7 1.4 1.4 8.1
0.3 0.77 2.70 1.3 1.1 1.4 1.0 0.3
2.8 x 0.8 with hole 0.6 7.0 0.84 2.90 1.8 1.3 12°     1.4 8.1
0.3 0.77 2.70 1.3 1.1     0.3
3.2 x 0.8 with dimple 0.6 7.0 0.84 3.25 1.8 1.3 12° 1.7 1.4 1.4 8.1
0.3 0.79 3.10 1.4 1.1 1.4 1.1 0.3
3.2 x 0.8 with hole 0.6 7.0 0.84 3.25 1.8 1.3 12°     1.4 8.1
0.3 0.79 3.10 1.4 1.1     0.3
3.2 x 0.5 with dimple 0.6 7.0 0.54 3.25 1.8 1.3 12° 1.7 1.4 1.4 8.1
0.3 0.48 3.10 1.4 1.1 1.4 1.1 0.3
3.2 x 0.5 with hole 0.6 7.0 0.54 3.25 1.8 1.3 12°     1.4 8.1
0.3 0.48 3.10 1.4 1.1     0.3
4.8 x 0.5 with dimple 0.9 6.2 0.54 4.80 2.8 1.5 12° 1.7 1.5 1.7 7.3
0.6 0.47 4.60 2.3 1.3 1.4 1.2 0.6
4.8 x 0.5 with hole 0.9 6.2 0.54 4.90 3.4 1.5 12°     1.7 7.3
0.6 0.47 4.67 3.0 1.3     0.6
4.8 x 0.8 with dimple 1.0 6.2 0.84 4.80 2.8 1.5 12° 1.7 1.5 1.8 7.3
0.7 0.77 4.60 2.3 1.3 1.4 1.2 0.7
4.8 x 0.8 with hole 1.0 6.2 0.84 4.90 3.4 1.5 12°     1.8 7.3
0.6 0.77 4.67 3.0 1.3     0.7
5.2 x 0.5 with dimple 1.0 6.2 0.54 5.30 2.8 1.9 12° 2.5 2.0 1.7 7.3
0.7 0.47 5.10 2.3 1.6 2.2 1.8 0.6
5.2 x 0.5 with hole 1.0 6.2 0.54 5.30 3.4 1.9 12°     1.7 7.3
0.7 0.47 5.10 3.0 1.6     0.6
5.2 x 0.8 with dimple 1.0 6.2 0.84 5.30 2.8 1.9 12° 2.5 2.0 1.8 7.3
0.7 0.77 5.10 2.3 1.6 2.2 1.8 0.7
5.2 x 0.8 with hole 1.0 6.2 0.84 5.30 3.4 1.9 12°     1.8 7.3
0.7 0.77 5.10 3.0 1.6     0.7
6.3 x 0.8 with dimple 1.0 7.8 0.84 6.40 4.1 2.0 12° 2.5 2.0 1.8 8.9
0.7 0.77 6.20 3.6 1.6 2.2 1.8 0.7
6.3 x 0.8 with hole 1.0 7.8 0.84 6.40 4.7 2.0 12°     1.8 8.9
0.5 0.77 6.20 4.3 1.6     0.7
Notes: 1. Included are dimensions for those nominal sizes corresponding with those found in IEC 61210. 2. In the table where two values are provided, the lesser value is the minimum permitted value and the larger is the maximum permitted value.

 

Figure 2

Dimensions of production and test tabs

 

Note 1 – For dimple and hole detent dimensions F, G, M, and N, see Figures 3 and 4.

Note 2 – Bevel "H" need not be a straight line if it is within the confines shown, and it may be a radius of "P".

Note 3 – "Q" dimension is for tabs without shoulders.

Note 4 – "L" dimension not specified.

 

Figure 3

Dimensions of dimple detents

Figure 4

Dimensions of hole detents

 

Figure 5

Double-ended test tab for temperature rise and heat cycling tests

 

Note: See Figures 2 to 4 and Table 2 or 3.

 

Figure 6

Connection and arrangement for temperature and current cycling tests

Reviews

There are no reviews yet.


Be the first to review “UL 310 Table 3 ( Ninth Edition ) Test Tab For Safety For Electrical Quick – Connect Terminals”

Related products