UL859 Hair Dryer Temperature Test System / UL859-Figure 44.4 Spacings On Thermocouple Grid

Product Details:

Place of Origin: China
Brand Name: Kingpo
Certification: Calibration Certificate
Model Number: UL859-figure 44.4

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: To be quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: 20 working days
Payment Terms: T/T
Supply Ability: 1000 pcs

Description

Detail Information

Standard: UL859-figure 44.4 Material: Glass Epoxy Board+Wood+aluminum Thermocouple Type: K / T Type Thermocouple Length: 1000mm Glass Epoxy Board Thickness: 1.6mm Wood Thickness: 3.2mm High Light:

abrasion resistance test machine

,

tv signal tester

Product Description

UL859 Hair dryer temperature test system | UL859-figure 44.4 spacings on thermocouple grid

 

The thermocouple grid assembly is to consist of two pieces of 1/16-inch (1.6-mm) thick glass epoxy board of the configuration and dimensions shown in Figure 44.4. The two boards are to be separated 1/8-inch (3.2-mm) by one 5-1/4- by 1/4- by 1/8-inch (133- by 6.4- by 3.2-mm) wood spacer at the top and bottom edges. Each spacer is to be secured by four 4 -40 by 3/8-inch countersunk flat head machine screws. Each end screw is to be threaded from the face of the assembly into a nut against the rear epoxy board. Each of the middle screws is to be located approximately 1-1/2 inches (38.1 mm) from the nearest longer edge of the board and threaded from the face into a standoff leg of a sheet aluminum back plate. The 5-1/2 by 3-1/4 inch (140 by 83 mm) stand-off back plate is to consist of sheet aluminum hat is 0.05 inch (1.3 mm) thick, having a minimum 7/16-inch (11.1-mm) wide integral standoff leg formed at each corner by means of an extension of the metal being bent in two successive 90-degree angles to cause the back plate to stand away from the rear epoxy board a distance of 1/4 inch. The back plate is to be secured to the center 5-1/2 by 3-1/4 inch section of the board. The board assembly is to be provided with 53 thermocouples rated 30 AWG (0.05 mm2). The thermocouples are to be located on the grid spaced as shown in Figure 44.4. The thermocouples are to be passed through the two thicknesses of glass epoxy board, and the thermocouple junction is to be cemented to the face of the board using epoxy cement, as shown in Figure 44.5.

 

 

Reviews

There are no reviews yet.


Be the first to review “UL859 Hair Dryer Temperature Test System / UL859-Figure 44.4 Spacings On Thermocouple Grid”

Related products